NIPPON-PID Controller 2020MVC
NipponsPID Contollers 2020MVC is a useful tool in MOTORISED valve controls.
Application: | Motorised Valve Control |
Outputs: | Separate forward and reverse outputs. |
Feedback and Indication | Valve Position Indicator |
Menu: | Advanced interactive parameter presentation |
Communication: | Easy Connection through digital communication |
- Universal Input
- PID Control
- Profiler
- MODBUS enabled
- Specifications
Table A:
INPUT | SENSOR | RANGE | ACCURACY |
---|---|---|---|
R.T.D. | PT-100 | -200 to 600 °C | ± 1 °C |
PT-1000 | 0 to 500 °C | ± 1 °C | |
THERMOCOUPLES | Chromel/Alumel (K) | 0 to 1300 °C | ± 1 °C |
Iron - Constantan (J) | 0 to 750 °C | ± 1 °C | |
Copper-Constantan (T) | -200 to 350 °C | ± 1 °C | |
Pt / Rh (R or S) | 0 to 1700°C | ± 1 °C | |
D.C. LINEAR INPUTS | 4 to 20 mA / 0 to 20 mA | User Programmable | ± Least count |
± 50 mV, ± 100 mV, ± 200 mV, ± 250 mV | User Programmable | ± Least count | |
± 1V, ± 3.3V, ± 5V, ± 10V | User Programmable | ± Least count |
Specification :
Input | ONE UNIVERSAL Input Thermocouples : J,K,T,R,S RTD's : PT-100, PT-1000 DC mA : 0 – 20 mA, 4 – 20 mA (Maximum 12 Volts) DC mV : ± 50 mV, ± 100 mV, ± 200 mV, ± 250 mV DC Volts : ± 1V, ± 3.3V, ± 5V, ± 10V |
---|---|
Range | Refer 'table A'' |
Ambient | Compensation automatic, ambient 0-60 °C |
Resolution | 1 or 0.1 or .01 or .001 programmable |
Display | Super bright in 4 + 4 format , with NO BLINK programming technique
|
Ananciation L.E.D's | 7 L.E.D.'s , 3 mm , multi colour, 3 for O/P's, 1 each for A/M, Alarm, Profile, Soak Time |
Parameter Setting | By soft touch, Elegant, Sturdy membrane keys & User friendly menu driven software |
Outputs | THREE, Programmable outputs with modular attachments
|
Note |
|
INPUT Control Outputs Rating | Relay SPST 230V / 3 Amp, 12 volts DC pulses for , 4-20 mA (Load 450 ohms) | ||
---|---|---|---|
CONTROLS | |||
|
PID / On-OFF / TP
|
||
|
|
||
|
Heat / Cool / Heat-Cool | ||
|
Provided | ||
|
|
||
|
Provided, 0 to 100% | ||
ALARMS | Assigned for O/P2 and O/P3 Alarm Types : Low / High /Band /Deviation / End of Profile Alarm Acknowledge : Latchable / Unlatchable Alarm Inhibit : Available | ||
Retransmission | 4-20 mA or 20-4 mA or 0-20 mA or 20-0 mA programmable, Non-isolated, Retransmission assign for O/P 2 and O/P 3 Provided on request | ||
Communication | RS485, 2-Wire, Half duplex RS485 MODBUS on request, MODBUS RTU or ASCII Baud Rate Programmable 1200/2400/4800/9600, contact factory for higher Baud Rates | ||
PROFILER | 2 Profile Programmes / 8 Segments Each
|